IT运维管理,创造商业价值!
中国IT运维网首页 | 资讯中心 | 运维管理 | 信息安全 | CIO视界 | 云计算 | 最佳案例 | 运维资源 | 专题策划 | 知识库 | 论坛

给大家分享一个Vlan小实验(1)

2008年05月23日
中国IT实验室/
 一、场景设置
 
 
    二、具体实现
    首先,将所有的PC配置在192.168.10.0/24这个网络,并测试连通性:
    PC1----192.168.10.2
    PC2----192.168.10.3
    PC3----192.168.10.4
    PC4----192.168.10.5
    PC1àPC2
    C:>ping 192.168.10.3
    Pinging 192.168.10.3 with 32 bytes of data:
    Reply from 192.168.10.3: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.3: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.3: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.3: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.3: bytes=32 time=60ms TTL=241
    Ping statistics for 192.168.10.3:     Packets: Sent = 5, Received = 5, Lost = 0 (0% loss),
    Approximate round trip times in milli-seconds:
         Minimum = 50ms, Maximum =  60ms, Average =  55ms
    PC1àPC3
    C:>ping 192.168.10.4
    Pinging 192.168.10.4 with 32 bytes of data:
    Reply from 192.168.10.4: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.4: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.4: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.4: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.4: bytes=32 time=60ms TTL=241
    Ping statistics for 192.168.10.4:     Packets: Sent = 5, Received = 5, Lost = 0 (0% loss),
    Approximate round trip times in milli-seconds:
         Minimum = 50ms, Maximum =  60ms, Average =  55ms
    PC1àPC4
    C:>ping 192.168.10.5
    Pinging 192.168.10.5 with 32 bytes of data:
    Reply from 192.168.10.5: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.5: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.5: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.5: bytes=32 time=60ms TTL=241
    Reply from 192.168.10.5: bytes=32 time=60ms TTL=241
    Ping statistics for 192.168.10.5:     Packets: Sent = 5, Received = 5, Lost = 0 (0% loss),
    Approximate round trip times in milli-seconds:
         Minimum = 50ms, Maximum =  60ms, Average =  55ms
    由此可见,网络连接正常。
    然后,在交换机上配置Vlan:
    Switch>enable
    Switch#vlan database
    Switch(vlan)#vlan 2 name Vlan2
    VLAN 2 added:
        Name:Vlan2
    Switch(vlan)#vlan 3 name Vlan3
    VLAN 3 added:
        Name:Vlan3
    Switch(vlan)#exit